Home >
Lafarge Plasterboard >
Acoustic Systems
ACOUSTIC SYSTEMS
Technical Data :
MastaBoard Soundshield Systems |
|
|
MastaBoard Soundshield Systems
|
Description:
Lafarge MastaBoard Soundshield Systems are recommended for the installation of acoustic wall and floor / ceiling systems in residential dwellings class 1 and 2. The high-density core of Lafarge MastaBoard Soundshield achieves enhanced acoustic qualities and an improved level of resistance to fire. Lafarge MastaBoard Fireshield, providing fire protection for timber and steel structures also forms part of this system.
To achieve the best Rw from acoustic installation systems for each room, the room type, design and position of doors and windows (creating leaks and gaps ideal for sound to travel) as well as appliances, should also be considered.
What Rw / STC is recommended in the walls / ceilings in the home?
The table below shows airborne sound insulation requirements in a number of countries.
| Country |
Airborne Sound Insulation |
Impact Sound Insulation |
Australia
(existing BCA) |
Generally Rw 45 but Rw 50 for walls between a habitable room (not kitchen) in one sole occupancy unit and a bathroom, kitchen etc in an adjacent sole occupancy unit |
No criteria other than in general construction terms and "satisfactory" for wall impact. |
Australia
(recommended)
|
Rw 55 laboratory tests or Rw 50 site DnT,w |
WIC 50
IIC of 50 with concessions |
|
Great Britain
|
Use one of a number of approved constructions, each of which may be shown to provide a sound transmission loss under laboratory conditions of 52-55 |
L’ntw not more than 61. This value is equivalent to IIC 54. |
|
Germany
|
Rw 54-57 depending on the type of building |
L’ntw not more than 53. This value is equivalent to IIC 62. |
|
Denmark
|
Rw 54 |
- |
|
New Zealand
|
Rw 55
|
IIC 55 |
|
U.S.A.
|
STC (Rw) 50 (DnTw 45) |
IIC 50 (45 if field verified) |
Note: DnT,w is Weighted Sound Level Difference i.e. the site performance for airborne sound. (Ref: Australian Building Codes Board, Regulation Document RD 2001/02 of January 2001, Proposal to change the sound insulation provisions of the Building Code of Australia.)
The Lafarge MastaBoard Soundshield Acoustic Systems’ recommendations below show how to control noise within today’s Australian home.
|
Wall to wall
|
STC/Rw |
Floor to Ceiling |
STC/Rw |
| Bedroom to Bedroom |
40-45 |
Bedroom to Bedroom |
35-50+ |
|
Lounge to Kitchen
|
30-35
|
Lounge to Kitchen
|
50+
|
| Bathroom to Bedroom |
45-50
|
Bathroom to Bedroom
|
45
|
| Study to Home theatre |
50+
|
Study to Home theatre
|
50+
|
|
Home theatre to laundry
|
50+
|
Home theatre to laundry
|
50+
|
Materials
Lafarge MastaBoard products used in the systems recommended in this bulletin are available in the following sizes:
| MastaBoard |
Size |
Pack Size |
Weight kg/sqm |
| Soundshield |
10 x 1200 x 3000 |
60
|
8.4
|
|
Fireshield
|
13 x 1200 x 2477 3600
16 x 1200 x 2477 3600
|
50
50 |
10.5
12.25
|
|
Multishield
|
16 x 1200 x 2700 3000
|
30
|
12.45
|
More comprehensive construction details and installation information is available in Lafarge MastaBoard Soundshield System's Technical Bulletin. It can be downloaded in a PDF format from below:
MastaBoard Soundshield Systems (6.2Mb)
|
|
|
All products contained herein © Lafarge Plasterboard. Page layout © 1996-2008 Architecture Media (Selector) Pty Ltd. All rights reserved.
|
|
|