Home >
Bristile Roofing >
Roof Tiles
ROOF TILES
Appraisals, Tests :
Index |
|
Standards
- Bristile Roof Tiles products comply with the following standard: AS2049-2002 Roof Tiles.
- Bristile Roof Tiles fixing complies with the following standard: AS 2050-2002
- Installation of Roof Tiles. Bristile Roof Tiles complies with the following standard when installing sarking: AS/NZ 4200.2-1994 Installation of Foil.
| Property |
Requirement |
Test |
| Transverse Breaking Load Strength |
Average > 4.0 N/mm
Minimum > 3.325 N/mm |
ASA 4046.3 |
| Comprehensive Strength (Cube) @28 Days |
> 30 Mpa
(4280 p.s.i.) |
AS1012 Part 9 |
| Water Absorption |
10% Water by weight |
AS 4046.43 |
| Permeability |
No drips for 2 hours under static 50 mm head of water. |
AS 4046.5 |
| Fire Resistance |
Rated Incombustible |
ASTME108 |
| Width |
±2.0% Nominal Size |
AS 2049 |
| Length |
±2.0% Nominal Size |
| Thickness |
±10.0% Nominal Size |
| Markings |
All tiles permanently marked with manufacturer’s brand name |
AS 2049 |
| Distortion |
No gap to exceed 5 mm. |
AS 4046.1 |
| Squareness and Lug Support |
All tiles self-supporting. No side out of square more than 1.5% |
AS 4046.2 |
| Freeze Thaw |
Tiles not to have significant or extreme surface breakdown as specified in the standard |
AS 4046.6 |
| Resistance to Salt |
Tiles not to have significant or extreme surface breakdown as specified in the standard |
AS 4046.7 |
|